Continued from preceding page.
Parameter
Symbol
Conditions
[DSP3.25V Output (VCC = 13.2 V, VSTBY = 5 V, IO7 = 100 mA)]
Output voltage
VO7
Dropout voltage
VDROP7 VO2 = 3.104 V
Line regulation
VOLN7 4.996 V VCC 18 V
Load regulation
VOLD7 0 IO7 100 mA
Peak output current
IOP7
Output short current
(reference value)
IOSC7
Output off voltage
VO7 OFF
[AMP + B Output (VCC = 13.2 V, VSTBY = 5 V, IO8 = 100 mA)]
Output voltage
VO8
Dropout voltage
VDROP8
Peak output current
IOP8
Output short current
(reference value)
IOSC8
Output off voltage
VO8 OFF
[ANT + B Output (VCC = 13.2 V, VSTBY = 5 V, IO9 = 250 mA)]
Output voltage
VO9
Dropout voltage
VDROP9
Peak output current
IOP9
Output short current
(reference value)
IOSC9
Output off voltage
VO9 OFF
[CAP MR Output (VCC = 13.2 V, VSTBY = 5 V, IO10 = 10 mA)]
Dropout voltage
VDROP10
Output sink current
IO10
[P1 (ILL) Output (VCC = 13.2 V, VSTBY = 5 V, IO11 = 10 mA)]
Dropout voltage
VDROP11
Output sink current
IO11
[P2 (LCD) Output (VCC = 13.2 V, VSTBY = 5 V, IO12 = 10 mA)]
Dropout voltage
VDROP12
Output sink current
IO12
[P3 (CAP MR) Output (VCC = 13.2 V, VSTBY = 5 V, IO13 = 10 mA)]
Dropout voltage
VDROP13
Output sink current
[Thermal Protection Circuit]
IO13
Operating temperature *3
TSD
VO1 and VO2 operation
VO3 to VO13 linked to VO1 and VO2 operation.
Ratings
Unit
min
typ
max
3.104
100
3.25
3.396
V
1.0
1.4
V
50
75 mV
100
150 mV
mA
420
mA
0.2
V
11.7
12.2
1
100
300
V
1.5
V
mA
mA
0.2
V
11.7
12.2
1
250
700
V
1.5
V
mA
mA
0.2
V
0.4
0.8
V
10
mA
0.4
0.8
V
10
mA
0.4
0.8
V
10
mA
0.4
0.8
V
10
mA
150
175
°C
Notes on items *1 to *3.
(1) VDD reset block (*1)
• The reset detection function detects the level of VDD5V input to VDD IN.
• This reset function operates correctly when the VDD IN voltage is over 0.5 V, but is undefined when VDD IN is under 0.5 V. The reset voltage must never
exceed VDD IN.
• The allowable range for the threshold voltage has a tolerance of ±4.7%.
(2) BAT and ACC reset blocks (*2)
• These reset detection outputs must operate correctly when the VDD IN voltage is over 2 V. The reset voltages must never exceed VDD IN.
• The ACC detection function has no region where detection is unpredictable according to the value of the voltage detected. That is, the low level will be
detected correctly when ACC IN is 0 V.
• The allowable range for the threshold voltage has a tolerance of ±3.2%.
(3) Thermal protection and operating temperature (*3)
• The values shown are design target values and are not tested.