KF00
ELECTRICAL CHARACTERISTICS FOR KF27 (refer to the test circuits, Tj = 25°C, CI = 0.1 µF,
CO = 2.2 µF unless otherwise specified.)
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
VO Output Voltage
IO = 50 mA, VI = 4.7 V
2.646 2.7 2.754 V
IO = 50 mA, VI = 4.7 V, Ta = -25 to 85°C
2.592
2.808
VI Operating Input Voltage
IO = 500 mA
20
V
IO Output Current Limit
1
A
VO Line Regulation
VI = 3.7 to 20 V, IO = 5 mA
2
12
mV
VO Load Regulation
VI = 4 V,
IO = 5 to 500 mA
2
50
mV
Id Quiescent Current
VI = 3.7 to 20V, IO = 0mA (ON MODE)
0.5
1
mA
VI = 4 to 20V, IO = 500mA
12
VI = 6 V
(OFF MODE)
50
100
µA
SVR Supply Voltage Rejection
IO = 5 mA
VI = 4.7 ± 1 V
f = 120 Hz
82
dB
f = 1 KHz
77
f = 10 KHz
60
eN Output Noise Voltage
B = 10 Hz to 100 KHz
50
µV
Vd Dropout Voltage
IO = 200 mA
0.2 0.35
V
IO = 500 mA
0.4
0.7
VIL Control Input Logic Low
Ta = -40 to 125°C
0.8
V
VIH Control Input Logic High Ta = -40 to 125°C
2
V
II Control Input Current
VI = 6 V,
VC = 6 V
10
µA
CO Output Bypass Capacitance ESR = 0.1 to 10
IO = 0 to 500 mA
2
10
µF
ELECTRICAL CHARACTERISTICS FOR KF30 (refer to the test circuits, Tj = 25°C, CI = 0.1 µF,
CO = 2.2 µF unless otherwise specified.)
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
VO Output Voltage
IO = 50 mA, VI = 5 V
2.94
3
3.06
V
IO = 50 mA, VI = 5 V, Ta = -25 to 85°C
2.88
3.12
VI Operating Input Voltage
IO = 500 mA
20
V
IO Output Current Limit
1
A
VO Line Regulation
VI = 4 to 20 V,
IO = 5 mA
2
12
mV
VO Load Regulation
VI = 4.3 V,
IO = 5 to 500 mA
2
50
mV
Id Quiescent Current
VI = 4 to 20V, IO = 0mA (ON MODE)
0.5
1
mA
VI = 4.3 to 20V, IO = 500mA
12
VI = 6 V
(OFF MODE)
50
100
µA
SVR Supply Voltage Rejection
IO = 5 mA
VI = 5 ± 1 V
f = 120 Hz
81
dB
f = 1 KHz
76
f = 10 KHz
60
eN Output Noise Voltage
B = 10 Hz to 100 KHz
50
µV
Vd Dropout Voltage
IO = 200 mA
0.2 0.35
V
IO = 500 mA
0.4
0.7
VIL Control Input Logic Low
Ta = -40 to 125°C
0.8
V
VIH Control Input Logic High Ta = -40 to 125°C
2
V
II Control Input Current
VI = 6 V,
VC = 6 V
10
µA
CO Output Bypass Capacitance ESR = 0.1 to 10
IO = 0 to 500 mA
2
10
µF