datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

IL485W View Datasheet(PDF) - RHOPOINT COMPONENTS

Part Name
Description
View to exact match
IL485W
RHOPOINT
RHOPOINT COMPONENTS RHOPOINT
IL485W Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
IL485W
Driver Section
Electrical specifications are Tmin to Tmax and VDD = 4.5 V to = 5.5 V unless otherwise stated.
Parameters
Symbol
Min.
Typ.(5)
Input Clamp Voltage
Output voltage
Differential Output Voltage(2)
Differential Output Voltage(2)
Differential Output Voltage(2)(6)
Change in Magnitude of Differential
Output Voltage(7)
VIK
VO
|VOD1|
|VOD2|
VOD3
Δ|VOD|
0
1.5
1.5
2.5
1.5
Common Mode Output Voltage
Change in Magnitude of Common
Mode Output Voltage(7)
Output Current(4) Output Disabled
High Level Input Current
Low Level Input Current
VOC
Δ|VOC|
IO
IIH
IIL
Short-circuit Output Current
IOS
Supply Current
Parameters
Maximum Data Rate
Differential Output Prop Delay
Pulse Skew(10)
Differential Output Rise & Fall Time
Output Enable Time To High Level
Output Enable Time To Low Level
Output Disable Time From High Level
Output Disable Time From Low Level
Skew Limit(3)
IDD1
Symbol
tD(OD)
tS(P)
tT(OD)
tPZH
tPZL
tPHZ
tPLZ
tSK(LIM)
4
Switching Specifications
Min.
Typ.(5)
35
16
1
8
31
22
28
16
2
Max.
1.5
6
6
5
5
±0.2
3
1
±0.2
1
0.8
10
10
250
150
250
6
Max.
25
6
10
65
35
50
32
12
Units
V
V
V
V
V
V
V
V
mA
μA
μA
mΑ
mA
Units
Mbps
ns
ns
ns
ns
ns
ns
ns
ns
Test Conditions
IL = 18 mA
IO = 0
IO = 0
RL = 54 , VDD = 5 V
RL = 54 , VDD = 4.5 V
RL = 54 or 100
RL = 54 or 100
RL = 54 or 100
VO = 12 V
VO = 7 V
VI = 3.5 V
VI = 0.4 V
VO = 6 V
VO = 0 V
VO = 8 V
No Load
(Outputs Enabled)
Test Conditions
RL = 54 , CL = 50 pF
RL = 54 , CL = 50 pF
RL = 54 , CL = 50 pF
RL = 54 , CL = 50 pF
RL = 54 , CL = 50 pF
RL = 54 , CL = 50 pF
RL = 54 , CL = 50 pF
RL = 54 , CL = 50 pF
RL = 54 , CL = 50 pF
Notes (apply to both driver and receiver sections):
1. All voltage values are with respect to network ground except differential I/O bus voltages.
2. Differential input/output voltage is measured at the noninverting terminal A with respect to the inverting terminal B.
3. Skew limit is the maximum propagation delay difference between any two devices at 25°C.
4. The power-off measurement in ANSI Standard EIA/TIA-422-B applies to disabled outputs only and
is not applied to combined inputs and outputs.
5. All typical values are at VDD1,VDD2 = 5 V or VDD1= 3.3 V and TA = 25°C.
6. The minimum VOD2 with a 100 load is either ½ VOD1 or 2 V, whichever is greater.
7. Δ|VOD| and Δ|VOC| are the changes in magnitude of VOD and VOC, respectively, that occur when the input is changed from one logic state to
the other.
8. This applies for both power on and power off, refer to ANSI standard RS-485 for exact condition.
The EIA/TIA-422-B limit does not apply for a combined driver and receiver terminal.
9. Includes 8 ns read enable time. Maximum propagation delay is 25 ns after read assertion.
10. Pulse skew is defined as |tPLH – tPHL| of each channel.
11. The relevant test and measurement methods are given in the Electromagnetic Compatibility section on p. 6.
12. External magnetic field immunity is improved by this factor if the field direction is “end-to-end” rather than to “pin-to-pin” (see diagram on p. 6).
4
 