datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

TMP-5 View Datasheet(PDF) - Murata Power Solutions

Part Name
Description
View to exact match
TMP-5 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
TMP Models
Triple Output, High-Efficiency, Smaller-Package, 25-40 Watt, DC/DC Converters
Temperature Derating and Electrical Performance Curves
Q12 Models (25 Watts)
25
25
20
20
15
15
10
Natural Convection Cooling
150 Linear Feet Per Minute
5
300 Linear Feet Per Minute
0
–40 0 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
Ambient Temperature (°C)
Figure 2a. Temperature Derating Without Heat Sink
10
Natural Convection Cooling
150 Linear Feet Per Minute
5
300 Linear Feet Per Minute
0
–40 0 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
Ambient Temperature (°C)
Figure 2b. Temperature Derating With Heat Sink
Q48 Models (30 Watts)
30
30
25
25
20
20
15
Natural Convection Cooling
10
150 Linear Feet Per Minute
300 Linear Feet Per Minute
5
15
Natural Convection Cooling
10
150 Linear Feet Per Minute
300 Linear Feet Per Minute
5
0
–40 0 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
Ambient Temperature (°C)
Figure 3a. Temperature Derating Without Heat Sink
0
–40 0 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
Ambient Temperature (°C)
Figure 3b. Temperature Derating With Heat Sink
D24 Models (35 Watts)
35
35
30
30
25
25
20
20
15
Natural Convection Cooling
10
150 Linear Feet Per Minute
300 Linear Feet Per Minute
5
15
Natural Convection Cooling
10
150 Linear Feet Per Minute
300 Linear Feet Per Minute
5
0
–40 0 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
Ambient Temperature (°C)
Figure 4a. Temperature Derating Without Heat Sink
www.murata-ps.com
0
–40 0 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
Ambient Temperature (°C)
Figure 4b. Temperature Derating With Heat Sink
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TMP25-40W_B02 Page 4 of 6
 