datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

TMP-5/5-15/1-Q12-C View Datasheet(PDF) - Murata Power Solutions

Part Name
Description
View to exact match
TMP-5/5-15/1-Q12-C Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
TMP Models
Triple Output, High-Efficiency, Smaller-Package, 25-40 Watt, DC/DC Converters
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and "full-load" conditions, unless noted. ~
Input Voltage Range:
Q12 Models
INPUT
10-36 Volts (24V nominal)
€ Applying a voltage to the On/Off Control pin when no input power is applied to the con
verter can cause permanent damage to the converter.
 Listed specification is for input-to-output isolation. Input-to-case and output-to-case
isolation is 1000Vdc, minimum.
Absolute Maximum Ratings
D24 Models
Q48 Models
D48 Models
18-36 Volts (24V nominal)
18-75 Volts (48V nominal)
36-75 Volts (48V nominal)
Input Voltage:
Q12/D24 Models
Q48/D48 Models
44 Volts
88 Volts
Input Current
Input Filter Type
See Ordering Guide
Pi
Input Reverse-Polarity Protection
Current must be <6A. Brief
duration only. Fusing recommended.
Overvoltage Shutdown:
Q12 and D24 Models
Q48 and D48 Models
Reverse-Polarity Protection
On/Off Control (Pin 5) €
40 Volts
80 Volts
Yes (Instantaneous, 6A maximum)
Pin open = ON, (logic HI)
Output Overvoltage Protection
+5V Output
±12V Outputs
±15V Outputs
Output Current
6.8 Volts, limited duration
15 Volts, limited duration
18 Volts, limited duration
Current limited. Max. current and
short-circuit duration are model
Pin grounded = OFF (logic LO)
dependent.
Output
Storage Temperature
–40 to +105°C
VOUT Accuracy (50% load):
+5V Output
±12V or ±15V Outputs
Temperature Coefficient
±1%
±3%
±0.02% per °C
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in the
Performance/Functional Specifications Table is not implied.
Ripple/Noise (20MHz BW)
See Ordering Guide
Line/Load Regulation
See Ordering Guide
TECHNICAL NOTES
Efficiency
See Ordering Guide
Isolation Voltage 
1500Vdc, minimum
Isolation Capacitance
500pF
Current Limiting
Continuous, auto-recovery
Overvoltage Protection
Zener/transorb clamps, magnetic fdbk.
Dynamic Characteristics
Transient Response (50% load step) 300μsec max. to ±3% of final value
Switching Frequency
125kHz (±10%)
Environmental
Operating Temperature (ambient):
Without Derating
With Derating
Maximum Case Temperature
–40 to +70°C (Model dependent)
to +95°C
+95°C
Storage Temperature
–40 to +105°C
Relative Humidity
To +85°C / 85% RH, non-condensing
Physical
Safety
UL/cUL/EN/IEC 60950-1
Dimensions
2.04" x 3.04" x 0.55" (51.8 x 77.2 x 14mm)
Shielding
5-sided
Case Connection
Pin 4
Case Material
Aluminum, black anodized finish
with plastic header
Filtering and Noise Reduction
All TMP 25-40 Watt DC/DC Converters achieve their rated ripple and noise
specifications without the use of external input/output capacitors. In criti-
cal applications, input/output ripple and noise may be further reduced by
installing electrolytic capacitors across the input terminals and/or low-ESR
tantalum or electrolytic capacitors across the output terminals. Output
capacitors should be connected between their respective output pin (pin 6, 7
or 9) and Common (pin 8). The caps should be located as close to the power
converters as possible. See Figure 7. Typical values are listed in the tables
below. In many applications, using values greater than those listed will yield
better results.
To Reduce Input Ripple
Q12, D24 Models
Q48, D48 Models
47μF, 50V
10μF, 100V
To Reduce Output Ripple
+5V Output
±12/15V Outputs
47μF, 10V, Low ESR
22μF, 20V, Low ESR
In critical, space-sensitive applications, DATEL may be able to tailor the in-
ternal input/output filtering of these units to meet your specific requirements.
Contact our Applications Engineering Group for additional details.
Input Fusing
Flammability Rating
Pin Material
Weight
UL94V-0
Gold-plated copper alloy over nickel
underplate
6 ounces (170 grams)
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For DATEL TMP DC/
DC Converters, you should use slow-blow type fuses with values no greater
than the following:
~ These converters require a minimum 10% loading on their primary output and 20%
loading on each auxiliary output to maintain specified regulation. Operation under no-load
conditions will not damage these devices; however they may not meet all listed specifica
tions.
 "Full load" varies by part number and is determined by the input voltage range as indi
cated by the part number suffix. See Technical Notes and Output Power Considerations.
VIN Range
Q12
D24
Q48
D48
Fuse Value
4A
4A
3A
2A
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TMP25-40W_B02 Page 3 of 6
 

Share Link: 