Absolute Maximum Ratings at TA = 25°C
Parameter
Peak Forward Current
Average Forward Current[1]
DC Current[2]
Reverse Voltage (IR = 100 µA)
Transient Forward Current[4]
(10 µsec Pulse)
LED Junction Temperature
Operating Temperature Range
HER/Orange
90
25
30
5
500
110
-55 to +100
Yellow
60
20
20
5
500
Green
90
25
30
5
500
110
-55 to +100
110
-20 to +100
Units
mA
mA
mA
V
mA
°C
°C
Storage Temperature Range
Lead Soldering Temperature
[1.6 mm (0.063 in.) from body]
-55 to +100
260°C for 5 seconds
Notes:
1. See Figure 5 (HER/Orange), 10 (Yellow), or 15 (Green/Emerald Green) to establish pulsed operating conditions.
2. For Red, Orange, and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red, Orange, and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.
Electrical Characteristics at TA = 25°C
Symbol
Description
Device
HLMP-
IV Luminous Intensity
High Efficiency Red
1300
1301
1302
1385
Orange
K400
K401
K402
Yellow
1400
1401
1402
1485
Green
1503
1523
1585
Emerald Green
K600
Test
Min. Typ. Max. Units Conditions
1.3 5.0
2.1 5.5
3.4 7.0
8.6 11.0
mcd IF = 10 mA
1.3 5.0
2.1 5.5
3.4 7.0
1.4 5.0
2.2 6.0
3.6 7.0
5.7 10.0
1.0 5.0
2.6 7.0
4.2 8.5
1.0 4.5
1-135