datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

HLMP-1450-1.0O001 View Datasheet(PDF) - HP => Agilent Technologies

Part Name
Description
View to exact match
HLMP-1450-1.0O001
HP
HP => Agilent Technologies HP
HLMP-1450-1.0O001 Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
2
Part Numbering System
HLMP - x x xx - x x x xx
Mechanical Option
00: Bulk
01: Tape & Reel, Crimped Leads
02: Tape & Reel, Straight Leads
Color Bin Options
0: Full Color Bin Distribution
Maximum Iv Bin Options
0: Open (no max. limit)
Others: Please refer to the Iv Bin Table
Minimum Iv Bin Options
Please refer to the Iv Bin Table
Viewing Angle
50: 55 degrees
Color Options
3: GaP HER
4: GaP Yellow
5: GaP Green
Package Options
1: T-1 (3 mm)
Absolute Maximum Ratings
Parameter
Peak Forward Current
Average Forward Current
DC Current
Reverse Voltage
Transient Forward Current (10 µsec Pulse)
LED Junction Temperature
Operating Temperature Range
Storage Temperature Range
Lead Soldering Temperature
[1.6 mm (0.063 in.) from body]
HER
90
25
30
5
500
110
-55 to +100
Yellow
Green
60
90
20
25
20
30
5
5
500
500
110
110
-55 to +100
-20 to +100
-55 to +100
260°C for
5 Seconds
Units
mA
mA
mA
V
µA
°C
°C
Notes:
1. See Figure 5 (HER/Orange), 10 (Yellow), or 15 (Green/Emerald Green) to establish pulsed operating conditions.
2. For Red, Orange, and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at
0.2 mA/°C.
3. For Red, Orange, and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from
50°C at 1.6 mW/°C.
4. The transient peak current is the maximum nonrecurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]