IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCPL-2211/2212 Option 060 ONLY)
Description
Symbol
Installation classification per DIN VDE 0110/1.89, Table 1
  for rated mains voltage ≤300 V rms
  for rated mains voltage ≤450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
VIORM
Input to Output Test Voltage, Method b*
  VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
  Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
  VIORM x 1.5 = VPR, Type and sample test,
  tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
  (Maximum values allowed in the event of a failure,
  also see Figure 12, Thermal Derating curve.)
   Case Temperature
   Input Current
   Output Power
Insulation Resistance at TS, VIO = 500 V
VPR
VIOTM
TS
IS,OUTPUT
PS,OUTPUT
RS
Characteristic
Units
I-IV
I-III
55/85/21
2
630
V peak
1181
V peak
945
V peak
6000
V peak
175
°C
230
mA
600
mW
≥109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-