IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (OPTION 060 ONLY)
Description
Symbol
Installation classification per DIN VDE 0110/1.89, Table 1
  for rated mains voltage ≤300 V rms
Characteristic
8 Pin DIP
SO-8
I-IV
I-III
  for rated mains voltage ≤450 V rms
I-III
Climatic Classification
55/100/21
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
2
Maximum Working Insulation Voltage
VIORM
630
Input to Output Test Voltage, Method b*
  VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
1181
  Partial Discharge < 5 pC
560
1050
Input to Output Test Voltage, Method a*
  VIORM x 1.5 = VPR, Type and sample test,
  tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
  (Maximum values allowed in the event of a failure,
  also see Figure 9, Thermal Derating curve.)
   Case Temperature
   Input Current
   Output Power
Insulation Resistance at TS, VIO = 500 V
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RS
945
6000
175
230
600
≥ 109
840
4000
175
150
600
≥ 109
Units
V peak
V peak
V peak
V peak
°C
mA
mW
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW135/6 ONLY)
             Description
Symbol
Installation classification per DIN VDE 0110/1.89, Table 1
  for rated mains voltage ≤600 V rms
  for rated mains voltage ≤1000 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
VIORM
Input to Output Test Voltage, Method b*
  VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
  Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
  VIORM x 1.5 = VPR, Type and sample test,
  tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
  (Maximum values allowed in the event of a failure,
  also see Figure 9, Thermal Derating curve.)
   Case Temperature
   Input Current
   Output Power
Insulation Resistance at TS, VIO = 500 V
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RS
Characteristic
Units
I-IV
I-III
55/85/21
2
1414
V peak
2652
V peak
2121
V peak
8000
V peak
150
°C
400
mA
700
mW
≥ 109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.