datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

HCPL-050L-060E View Datasheet(PDF) - HP => Agilent Technologies

Part Name
Description
View to exact match
HCPL-050L-060E
HP
HP => Agilent Technologies HP
HCPL-050L-060E Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
Insulation and Safety Related Specifications
Parameter
Symbol
8-Pin DIP
(300 Mil)
Value
Minimum External Air
L (101) 7.1
Gap (External Clearance)
Minimum External Tracking L (102) 7.4
(External Creepage)
Minimum Internal Plastic
0.08
Gap (Internal Clearance)
Tracking Resistance
CTI
200
(Comparative Tracking
Index)
Isolation Group
IIIa
SO-8
Value
4.9
4.8
0.08
200
IIIa
Units
mm
mm
mm
Volts
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-2Insulation Related Characteristics
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 150 V rms
for rated mains voltage 300 V rms
for rated mains voltage 600 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test
with tm = 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and Sample Test,
tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RS
PDIP Option 060
I-IV
I-III
55/85/21
2
630
1181
945
6000
175
230
600
109
SO-8 Option 60
I-IV
I-III
I-II
55/85/21
2
566
1063
849
4000
150
150
600
109
Units
Vpeak
Vpeak
Vpeak
Vpeak
˚C
mA
mW
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
5
 