HA16116FP/FPJ, HA16121FP/FPJ
Overcurrent Detection Value Setting
The overcurrent detection value VTH for this IC series is 0.2 V (Typ) and the bias current is 200 µA (Typ)
The power MOS FET peak current value before the current limiter goes into operation is derived from the
following equation.
ID =
VTCL (RF + RCS) IBCL
RCS
Here VTH = VIN – VCL = 0.2 V, VCL is a voltage referd on GND.
Note that CF and RCS form a low-pass filter, determined by their time constants, that prevents malfunctions
from current spikes when the power MOS FET is turned on or off.
S.VIN
To other
circuitry
1k
200 A
CF 1800 PF
VCL
I BCL
CL
RF
240
RCS
0.05
OUT
Detection
output
(internal)
+
IN(—)
G
S
D
+
VIN
This circuit is an example
for step-down output use.
VO
Figure 8.1 Example for Step-Down Use
The sample values given in this figure are calculated from the following equation.
ID
=
0.2
V
(240
+ 0.05
0.05
)
×
200
µA
= 3.04 [A]
The filter cutoff frequency is calculated as follows.
1
1
fC =
2π CF RF
=
6.28 × 1800 pF × 240
= 370 [kHz]