Teccor® brand Thyristors
0.8 Amp Sensitive SCRs
Figure 12: Surge Peak On-State Current vs. Number of Cycles
100.0
10.0
1.0
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated
Value at Specified Case Temperature
Notes:
1. G ate control may be lost during and immediately
following surge current interval.
2. O verload may not be repeated until junction
temperature has returned to steady-state
rated value.
0.1
1
10
100
1000
Surge Current Duration -- Full Cycles
Figure 13: Simple Test Circuit for Gate Trigger Voltage and Current
Reset
Normally-closed
Pushbutton
Note: V1 — 0 V to 10 V dc meter
VGT — 0 V to 1 V dc meter
IG — 0 mA to 1 mA dc milliammeter
R1 — 1 k potentiometer
+
6VDC
100
To measure gate trigger voltage and current, raise gate
voltage (VGT) until meter reading V1 drops from 6 V to 1 V.
D.U.T.
V1
Gate trigger voltage is the reading on VGT just prior to V1
IGT
IG
IN4001
100
R1
dropping. Gate trigger current IGT Can be computed from
the relationship
1k
(1%)
VGT
IGT
=
IG-
_V__GT_
1000
Amps
where IG is reading (in amperes) on meter just prior to V1
dropping
Note: IGT may turn out to be a negative quantity (trigger
current flows out from gate lead). If negative current
occurs, IGT value is not a valid reading. Remove 1 k resistor
and use IG as the more correct IGT value. This will occur on
12 µA gate products.