datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

40IMX35D05D15-8-IZG View Datasheet(PDF) - Power-One Inc.

Part Name
Description
View to exact match
40IMX35D05D15-8-IZG
Power-One
Power-One Inc. Power-One
40IMX35D05D15-8-IZG Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
IMX35 Series Data Sheet
35 Watt Quad-Output DC-DC Converters
®
Electrical Output Data
General conditions:
– TA = 25 °C, unless TC is specified
– Pins 8 (shutdown or i), 6 (W), 5 (Trim or Trim1), and 1 (PUL) left open-circuit (not connected), unless specified.
Table 6: Output data per double-output power train (Vo1/Vo4 or Vo2/Vo3; each power train has 2 outputs)
Output
2x5V
2 x 12 V
2 x 15 V
Characteristics
Conditions
Vo1 Output voltage
Vo2
Vi nom
Io = 0.5 Io nom
Io nom Output current
20IMX Vi min to Vi max
40IMX
70IMX
110IMX
IoL
Current limit 1
20IMX Vi nom, TC = 25 °C
40IMX Vo = 93% Vo nom
70IMX
110IMX
Vo Line regulation
Vi min to Vi max, Io nom
Vo l Load regulation
Vo1/2 Output voltage noise
Vi nom
Io = (0.1 to 1) Io nom
Vi min to Vi max
2
I o = Io nom
3
Vo L
Co ext
Vo d
td
αVo
Output overvoltage limit. 4
Admissible capacitive load
per power train 5
Dynamic Voltage deviat.
load
regulation
Recovery time
Temperature coefficient
Vo /TC
Min. load 1%
produced after 2011
Vi nom
Io nom 1/2 Io nom
Vi min to Vi max
Io = (0.1 to 1) Io nom
min typ
4.95
4.94
max
5.05
5.06
2 × 1.35
2 × 1.4
2 × 1.4
2 × 1.4
3.5
3.8
3.8
3.8
±1
±3
80
40
115
130
0
6000
± 250
0.75
± 0.02
min typ max
11.88
11.86
12.12
12.14
2 × 0.65
2 × 0.70
2 × 0.70
2 × 0.70
1.8
2.0
2.0
2.0
±1
±3
120
60
115
130
0
680
± 480
0.75
±0.02
min typ max
14.85
14.82
15.15
15.18
2 × 0.55
2 × 0.60
2 × 0.60
2 × 0.60
1.5
1.7
1.7
1.7
±1
±3
150
70
115
130
0
470
± 520
0.75
±0.02
Unit
VDC
A
%
mVpp
%
µF
mV
ms
%/K
1 Both outputs of each power train connected in parallel. The current limit is primary side controlled. In the event of a sustained overload
condition, the thermal protection may cause the converter to shut down (restart on cool-down).
2 BW = 20 MHz, measured with an external capacitor of 1 µF across the output pins.
3 Measured with a probe according to EN 61204
4 The overvoltage protection is via a primary side second regulation loop, not tracking with Trim control.
5 Sum of the capacities on both outputs of each power train
BCD20009-G Rev AC, 06-May-2013