datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

D101ED View Datasheet(PDF) - MicroPower Direct, LLC

Part Name
Description
View to exact match
D101ED Datasheet PDF : 2 Pages
1 2
Model Selection Guide
Model
Number
D101ED
D102ED
D103ED
D104ED
D111ED
D112ED
D113ED
D114ED
D121ED
D122ED
D123ED
D124ED
Input
Voltage (VDC)
Nominal Range
Current (mA) Voltage
Full-Load No-Load (VDC)
5
4.5 - 5.5 285
30
5.0
5
4.5 - 5.5 263
30
9.0
5
4.5 - 5.5 259
30
12.0
5
4.5 - 5.5 256
30
15.0
12 10.8 - 13.2 115
12
5.0
12 10.8 - 13.2 107
12
9.0
12 10.8 - 13.2 107
12
12.0
12 10.8 - 13.2 104
12
15.0
24 21.6 - 26.4 58
7
5.0
24 21.6 - 26.4 54
7
9.0
24 21.6 - 26.4 55
7
12.0
24 21.6 - 26.4 55
7
15.0
Output 1
Output 2
Current Current Voltage Current Current
(mA, Max) (mA, Min) (VDC) (mA, Max) (mA, Min)
100.0
10.0
5.0
100.0
10.0
56.0
6.0
9.0
56.0
6.0
42.0
4.2
12.0
42.0
4.2
33.0
3.3
15.0
33.0
3.3
100.0
10.0
5.0
100.0
10.0
56.0
6.0
9.0
56.0
6.0
42.0
4.2
12.0
42.0
4.2
33.0
3.3
15.0
33.0
3.3
100.0
10.0
5.0
100.0
10.0
56.0
6.0
9.0
56.0
6.0
42.0
4.2
12.0
42.0
4.2
33.0
3.3
15.0
33.0
3.3
Efficiency
(%, Typ)
70
76
77
78
72
78
78
80
71
77
76
76
Fuse Rating
Slow-Blow
(mA)
500
500
500
500
250
250
250
250
125
125
125
125
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that an external ceramic
capacitor (approx approx 1 µF to 10 µF) be placed from each output to
common.
3. These units should not be operated with a load under 10% of full load.
Operation at no-load may cause damage to the unit.
4. These converters are specified for operation without external components.
However, in some applications the addition of input/ouput capacitors will
enhance stability and reduce output ripple. Recommended capacitor values
are:
Vin
5 VDC
12 VDC
24 VDC
Input
Capacitor
4.7 µF
2.2 µF
1.0 µF
Vout
5 VDC
9 VDC
12 VDC
15 VDC
Output
Capacitor
4.7 µF
2.2 µF
1.0 µF
0.47 µF
Block Diagram
For applications requiring very low output noise levels, a simple LC filter
should be effective.
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Derating Curve
Mechanical Dimensions
Pin Connections
Pin Function
1
+Vin
2
-Vin
4
-Vout 1
5
+Vout 1
6
-Vout 2
7
+Vout 2
Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.01 (±0.25)
Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com
 