80960HA/HD/HT
Table 22. 80960Hx AC Characteristics (Sheet 2 of 2)
Per conditions in Section 4.2, “Operating Conditions” on page 29 and Section 4.7.1, “AC Test Conditions” on page 37.
Symbol
Parameter
Min
Max
Units Notes
TIH2
Input Hold for READY, BTERM, HOLD, and
BOFF
2.5
ns
Relative Output Timings (1,2,3,6,10)
TAVSH1
TAVSH2
TAVEL1
TAVEL2
TNLQV
TDVNH
TNLNH
TNHQX
TEHTV
TTVEL
A31:2 Valid to ADS Rising
T–5
T+5
ns
BE3:0, W/R, SUP, D/C Valid to ADS Rising
T–5
T+5
ns
A31:2 Valid to DEN Falling
T–5
T+5
ns
BE3:0, W/R, SUP Valid to DEN Falling
T–5
T+5
ns
WAIT Falling to Output Data Valid
-5
5
ns
Output Data Valid to WAIT Rising
-5 + N*T
5 + N*T
ns
WAIT Falling to WAIT Rising
-4 + N*T
4 + N*T
ns
Output Data Hold after WAIT Rising
-5 + (N+1)*T 5 + (N+1)*T ns
DT/R Hold after DEN High
T/2 – 5
Infinite
ns
DT/R Valid to DEN Falling
80960HA T/2 – 4
ns
80960HD T/4 – 4
ns
80960HT T/6 – 4
ns
(10)
(10)
(10)
(10)
(10)
(4,10)
(4,10)
(5,10)
(10)
(10)
Relative Input Timings (1,7,10)
TIS7
XINT7:0, NMI Input Setup
6
ns
(9)
TIH7
XINT7:0, NMI Input Hold
2.5
ns
(9)
TIS8
RESET Input Setup
3
ns
(8)
TIH8
RESET Input Hold
T/4 + 1
ns
(8)
NOTE: See Table 23 “AC Characteristics Notes” on page 36 for all notes related to AC specifications.