CS4294
6.1.21 Extended Audio DAC1/ADC1 Rate (Index 40h)
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
SR15 SR14 SR13 SR12 SR11 SR10 SR9 SR8 SR7 SR6 SR5 SR4 SR3 SR2 SR1 SR0
SR[15:0] Extended Audio DAC1/ADC1 Sample Rate.
Default Read-only value BB80h, indicating 48 kHz sample rate.
6.1.22 Extended Audio DAC2/ADC2 (Index 44h)
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
SR15 SR14 SR13 SR12 SR11 SR10 SR9 SR8 SR7 SR6 SR5 SR4 SR3 SR2 SR1 SR0
SR[15:0] Extended Audio DAC2/ADC2 Sample Rate.
Default Read-only value BB80h, indicating 48 kHz sample rate.
6.1.23 Extended Audio DAC1/ADC1 Level (Index 46h)
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Mute
DAC3 DAC2 DAC1 DAC0 Mute
ADC3 ADC2
Mute[D15] Mute. Mutes the input of Extended Audio DAC1.
Mute[D7] Mute. Mutes the output of Extended Audio ADC1.
DAC[3:0] Extended Audio DAC1 attenuation. Least significant bit represents 1.5 dB with 00000 = 0 dB. The total
range is 0 dB to -22.5 dB.
ADC[3:2] Extended Audio ADC1 gain. Least significant bit represents 6 dB with 00 = 0 dB. The total range is 0 dB
to +18 dB.
Default 8080h indicating mute with 0 dB attenuation or gain.
When EAM of the AC Mode Control (Index 5Eh) is set, the Extended Audio DAC1 attenuation is
controlled by ML[4:0] of the Alternate Volume (Index 04h) register.
6.1.24 Extended AudioDAC2/ADC2 Level (Index 4Ah)
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Mute
DAC3 DAC2 DAC1 DAC0 Mute
ADC3 ADC2
Mute[D15] Mute. Mutes the input of Extended Audio DAC2.
Mute[D7] Mute. Mutes the output of Extended Audio ADC2.
DAC[3:0] Extended Audio DAC2 attenuation. Least significant bit represents 1.5 dB with 00000 = 0 dB. The total
range is 0 dB to -22 dB.
ADC[3:2] Extended Audio ADC2 gain. Least significant bit represents 6 dB with 00 = 0 dB. The total range is 0 dB
to +18 dB.
Default 8080h indicating mute with 0 dB attenuation or gain.
When EAM of the AC Mode Control (Index 5Eh) is set, the Extended Audio DAC2 attenuation is
controlled by MR[4:0] of the Alternate Volume (Index 04h) register.