datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

ADR292FRZ-REEL7 View Datasheet(PDF) - Analog Devices

Part Name
Description
View to exact match
ADR292FRZ-REEL7 Datasheet PDF : 20 Pages
First Prev 11 12 13 14 15 16 17 18 19 20
ADR291/ADR292
TERMINOLOGY
Line Regulation
Line regulation refers to the change in output voltage due to a
specified change in input voltage. It includes the effects of self-
heating. Line regulation is expressed as percent-per-volt, parts-
per-million-per-volt, or microvolts-per-volt change in input
voltage.
Load Regulation
The change in output voltage is due to a specified change in
load current and includes the effects of self-heating. Load
regulation is expressed in microvolts-per-milliampere, parts-
per-million-per-milliampere, or ohms of dc output resistance.
Long-Term Stability
Long-term stability refers to the typical shift of output voltage at
25°C on a sample of parts subjected to a test of 1000 hours at
125°C.
( ) ( ) ΔVOUT = VOUT t 0 VOUT t1
ΔVOUT
[ppm]
=
VOUT
(t 0 ) VOUT
( ) VOUT t 0
(t
1
)
×
10
6
where:
VOUT (t0) = VOUT at 25°C at Time 0.
VOUT (t1) = VOUT at 25°C after 1000 hours of operation at 125°C.
Temperature Coefficient
Temperature coefficient is the change of output voltage over
the operating temperature change, normalized by the output
voltage at 25°C, expressed in ppm/°C. The equation follows:
TCV O
[ppm/
°C]
=
VO (T2 )VO (T1 )
VO (25°C)× (T2 T1
)
×10
6
where:
VOUT (25°C) = VOUT at 25°C.
VOUT (T1) = VOUT at Temperature 1.
VOUT (T2) = VOUT at Temperature 2.
NC = no connect.
There are internal connections at NC pins that are reserved for
manufacturing purposes. Users should not connect anything at
the NC pins.
Thermal Hysteresis
Thermal hysteresis is defined as the change of output voltage
after the device is cycled through temperatures from +25°C to
−40°C, then to +85°C, and back to +25°C. This is a typical value
from a sample of parts put through such a cycle.
VOUTHYS = VOUT (25°C) VOUT_TC
VΟUT
HYS[ppm]
=
VOUT
(25°C) VOUT_TC
VOUT (25°C)
× 106
where:
VOUT (25°C) = VOUT at 25°C.
VOUT_TC = VOUT at 25°C after temperature cycle from +25°C to
−40°C, then to +85°C, and back to +25°C.
Rev. F | Page 12 of 20
 