ADP3623/ADP3624/ADP3625/ADP3633/ADP3634/ADP3635
SPECIFICATIONS
VDD = 12 V, TJ = −40°C to +125°C, unless otherwise noted.1
Table 1.
Parameter
SUPPLY
Supply Voltage Range
Supply Current
Standby Current
UVLO
Turn-On Threshold Voltage
Turn-Off Threshold Voltage
Hysteresis
DIGITAL INPUTS (INA, INA, INB, INB, SD)
Input Voltage High
Input Voltage Low
Input Current
SD Threshold High
SD Threshold Low
SD Hysteresis
Internal Pull-Up/Pull-Down Current
OUTPUTS (OUTA, OUTB)
Output Resistance, Unbiased
Peak Source Current
Peak Sink Current
SWITCHING TIME
OUTA, OUTB Rise Time
OUTA, OUTB Fall Time
OUTA, OUTB Rising Propagation Delay
OUTA, OUTB Falling Propagation Delay
SD Propagation Delay Low
SD Propagation Delay High
Delay Matching Between Channels
OVERTEMPERATURE PROTECTION
Overtemperature Warning Threshold
Overtemperature Shutdown Threshold
Temperature Hysteresis for Shutdown
Temperature Hysteresis for Warning
Overtemperature Warning Low
Symbol Test Conditions/Comments
VDD
ADP3633/ADP3634/ADP3635
VDD
ADP3623/ADP3624/ADP3625
IDD
No switching, INA, INA, INB, and INB disabled
ISBY
SD = 5 V
VUVLO_ON
VUVLO_ON
VUVLO_OFF
VUVLO_OFF
VDD rising, TA = 25°C, ADP3633/ADP3634/ADP3635
VDD rising, TA = 25°C, ADP3623/ADP3624/ADP3625
VDD falling, TA = 25°C, ADP3633/ADP3634/ADP3635
VDD falling, TA = 25°C, ADP3623/ADP3624/ADP3625
ADP3633/ADP3634/ADP3635
ADP3623/ADP3624/ADP3625
VIH
VIL
IIN
VSD_H
VSD_H
VSD_L
VSD_HYST
0 V < VIN < VDD
TA = 25°C
TA = 25°C
TA = 25°C
tRISE
tFALL
tD1
tD2
tdL_SD
tdH_SD
VDD = PGND
See Figure 20
See Figure 20
CLOAD = 2.2 nF, see Figure 3 and Figure 4
CLOAD = 2.2 nF, see Figure 3 and Figure 4
CLOAD = 2.2 nF, see Figure 3 and Figure 4
CLOAD = 2.2 nF, see Figure 3 and Figure 4
See Figure 2
See Figure 2
TW
TSD
THYS_SD
THYS_W
VOTW_OL
See Figure 6
See Figure 6
See Figure 6
See Figure 6
Open drain, −500 µA
1 All limits at temperature extremes guaranteed via correlation using standard statistical quality control (SQC) methods.
Min Typ Max Unit
9.5
18 V
4.5
18 V
1.2 3
mA
1.2 3
mA
8.0 8.7 9.5 V
3.8 4.2 4.5 V
7.0 7.7 8.5 V
3.5 3.9 4.3 V
1.0
V
0.3
V
2.0
V
0.8 V
−20
+20 µA
1.19 1.28 1.38 V
1.21 1.28 1.35 V
0.95 1.0 1.05 V
240 280 320 mV
6
µA
80
kΩ
4
A
−4
A
10 25 ns
10 25 ns
14 30 ns
22 35 ns
32 45 ns
48 75 ns
2
ns
120 135 150 °C
150 165 180 °C
30
°C
10
°C
0.4 V
Rev. A | Page 3 of 16
 