datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

ADP1046A-100-EVALZ View Datasheet(PDF) - Analog Devices

Part Name
Description
View to exact match
ADP1046A-100-EVALZ Datasheet PDF : 88 Pages
First Prev 41 42 43 44 45 46 47 48 49 50 Next Last
Data Sheet
ADP1046A
Table 10. Register 0x02—Fault Register 3 and Register 0x06—Latched Fault Register 3 (1 = Fault, 0 = Normal Operation)
Bits Bit Name
R/W Description
Register Action
7 OTP
R
Temperature is above OTP limit.
0x2F
Programmable
6 Fast OVP
R
Fast OVP threshold was exceeded.
0x37
Programmable
5 Share bus
R
Current share is outside regulation limit.
0x2A
Programmable
4 Constant current
R
Power supply is operating in constant current mode (constant 0x27
current mode is enabled).
None
3 Soft start
R
The reference is being ramped.
None
2 Line impedance
R
Line impedance between VS2 and VS3± is above limit.
0x35
None
1 Soft start filter
R
The soft start filter is in use.
0x5F
None
0 External flag
R
The external flag pin (FLAGIN) is set.
Programmable
Table 11. Register 0x03—Fault Register 4 and Register 0x07—Latched Fault Register 4 (1 = Fault, 0 = Normal Operation)
Bits Bit Name
R/W Description
Register Action
7 Volt-second balance R
Volt-second balance is at its maximum or minimum limit.
None
6 Modulation
R
Modulation is at its maximum or minimum limit.
0x2E
None
5 Reserved
R
Reserved.
None
4 Light load mode
R
The system is in light load mode.
0x3B
None
3 Reserved
R
Reserved.
None
2 ACSNS
R
The ac sense (comparator) amplitude is not correct.
Programmable
1 CRC fault
R
The EEPROM contents downloaded are incorrect.
Immediate shutdown
0 EEPROM unlocked R
The EEPROM is unlocked.
None
Table 12. Register 0x08 to Register 0x0D—Fault Configuration Registers
Register Name
Address Bits
Flag
Fault Configuration Register 1
0x08
[7:4]
CS1 fast OCP
[3:0]
CS1 accurate OCP
Fault Configuration Register 2
0x09
[7:4]
CS2 accurate OCP
[3:0]
Load OVP (VS2 or VS3)
Fault Configuration Register 3
0x0A
[7:4]
Local accurate OVP (VS1)
and fast OVP (VS1)
[3:0]
External flag input (FLAGIN)
Fault Configuration Register 4
0x0B
[7:4]
OTP
[3:0]
UVP
Fault Configuration Register 5
0x0C
[7:4]
CS2 reverse voltage
[3:0]
Voltage continuity
Fault Configuration Register 6
0x0D
[7:4]
Share bus
[3:0]
ACSNS
Shutdown Debounce
See Register 0x27 in Table 39
See Register 0x0E in Table 14
See Register 0x0E in Table 14
2 ms
2 ms (see Register 0x37
in Table 55)
10 ms
100 ms
10 ms
10 ms
100 ms
100 ms
10 ms
Rev. 0 | Page 49 of 88
 