PLL Frequency Synthesizer
ADF4108S
R COUNTER
The 14-bit R counter allows the input reference frequency to be divided down to produce the reference clock to the phase
frequency detector (PFD). Division ratios from 1 to 16,383 are allowed.
PHASE FREQUENCY DETECTOR AND CHARGE PUMP
The phase frequency detector (PFD) takes inputs from the R counter and N counter (N = BP + A) and produces an output
proportional to the phase and frequency difference between them. Figure 7 is a simplified schematic. The PFD includes a
programmable delay element that controls the width of the antibacklash pulse. This pulse ensures that there is no dead
zone in the PFD transfer function and minimizes phase noise and reference spurs. Two bits in the reference counter latch,
ABP2 and ABP1, control the width of the pulse (see Figure 10). Use of the minimum antibacklash pulse width is not
recommended.
Figure 7. PFD Simplified Schematic and Timing (in Lock)
MUXOUT AND LOCK DETECT
The output multiplexer on the ADF4108 allows the user to access various internal points on the chip. The state of MUXOUT
is controlled by M3, M2, and M1 in the function latch. Figure 11 shows the full truth table. Figure 8 shows the MUXOUT
section in block diagram form.
Lock Detect
MUXOUT can be programmed for two types of lock detect: digital lock detect and analog lock detect.
Digital lock detect is active high. When the lock detect precision (LDP) bit in the R counter latch is set to 0, digital lock detect
is set high when the phase error on three consecutive phase detector (PD) cycles is less than 15 ns. With LDP set to 1, five
consecutive cycles of less than 15 ns are required to set the lock detect. It stays set high until a phase error of greater than
25 ns is detected on any subsequent PD cycle.
The N-channel open-drain analog lock detect should be operated with an external pull-up resistor of 10 kΩ nominal. When
lock has been detected, this output is high with narrow, low going pulses.
ASD0016548
Rev.A
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.326.8703 © 2013 Analog Devices, Inc. All rights reserved.
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]