datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

ADCMP351AKS View Datasheet(PDF) - Analog Devices

Part Name
Description
View to exact match
ADCMP351AKS
ADI
Analog Devices ADI
ADCMP351AKS Datasheet PDF : 4 Pages
1 2 3 4
ADCMP350–ADCMP357
SPECIFICATIONS
(VCC=Full Operating Range, TA=-40°C to +125°C, unless otherwise noted.)
Parameter
SUPPLY
VCC Operating Voltage Range
VIN Operating Voltage Range
Supply Current
INTERNAL REFERENCE
ADCMP350/2/4/6
ADCMP351/3/5/7
VIN HYSTERESIS
INPUT BIAS CURRENT
THRESHOLD TEMPERATURE COEFFICIENT
VIN TO OUT DELAY
OUT/OUT VOLTAGE LOW
OUT/OUT VOLTAGE HIGH
OUT/OUT OPEN-DRAIN OUTPUT LEAKAGE CURRENT
Min
Typ
2.25
10
0.585
0.6
0.579
0.6
1.17
1.2
1.158
1.2
20
10
30
5
0.8xVcc
Preliminary Technical Data
Max
Units Test Conditions/Comments
3.6
V
22
V
15
µA
0.615
0.621
1.23
1.242
0.3
1
V
V
V
V
mV
nA
ppm/ºC
µs
V
V
µA
VCC=3.3V, TA=-40°C to +85°C
VCC=3.3V, TA=-40°C to +125°C
VCC=3.3V, TA=-40°C to +85°C
VCC=3.3V, TA=-40°C to +125°C
VCC=3.3V
VIN= VTH to (VTH-100mV)
VIN<VTH min, ISINK=1.2mA
VIN>VTH max, ISOURCE=500µA
VCC>VTH, OUT/OUT=22V
ABSOLUTE MAXIMUM RATINGS
Table 3. TA = 25°C unless otherwise noted.
Parameter
VCC
VIN
OUT, OUT (Open-Drain)
OUT, OUT (Push-Pull)
Operating Temperature Range
Storage Temperature Range
θJA Thermal Impedance, SC70
Lead Temperature
Soldering (10 sec)
Vapour Phase (60 sec)
Infrared (15 sec)
Rating
-0.3V to +6V
-0.3V to +25V
-0.3V to +25V
-0.3V to (VCC+0.3V)
-40°C to +125°C
-65°C to +150°C
146°C/W
300°C
215°C
220°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Rev. PrB | Page 2 of 4
 