DC Electrical Characteristics (Continued)
Symbol
Parameter
VCC
VCC—Cable TA 40qC to 85qC Units
(V)
(V)
Guaranteed Limits
Conditions
VOL
Maximum LOW
Level Output
An, HLH
Voltage
Bn, Yn
Bn, Yn
PLH
PLH
RD
Maximum Output
B1–B8, Y9–Y13
Impedance
Minimum Output
Impedance
B1–B8, Y9–Y13
3.0
3.0
3.0
3.0
3.0
3.0
3.0
4.5
3.0
3.0
3.0
4.5
3.3
3.3
3.3
5.0
3.3
3.3
3.3
5.0
0.2
0.4
0.8
0.77
0.95
0.9
60
55
30
35
IOL 50 PA
IOL 4 mA
V
IOL 14 mA
IOL 14 mA
IOL 84 mA
IOL 84 mA
(Note 5)(Note 7)
:
(Note 5)(Note 7)
RP
IIH
IIL
IOZH
IOZL
IOFF
Maximum Pull-Up
Resistance
Minimum Pull-Up
Resistance
Maximum Input
Current in
HIGH State
Maximum Input
Current in
LOW State
Maximum Output
Disable Current
(HIGH)
Maximum
Output Disable
Current (LOW)
Power Down
Output Leakage
B1–B8, Y9–Y13,
C14–C17
B1–B8, Y9–Y13
C14–C17
A9–A13, PLHIN,
HD, DIR, HLHIN
C14–C17
C14–C17
A9–A13, PLHIN,
HD, DIR, HLHIN
C14–C17
C14–C17
A1–A8
B1–B8
B1–B8
A1–A8
B1–B8
B1–B8
B1–B8, Y9–Y13,
PLH
3.3
3.3
3.3
5.0
3.3
3.3
3.3
5.0
3.6
3.6
3.6
3.6
3.6
5.5
3.6
3.6
3.6
3.6
3.6
5.5
3.6
3.6
3.6
3.6
3.6
5.5
3.6
3.6
3.6
3.6
3.6
5.5
0.0
0.0
1650
1650
1150
1150
1.0
50.0
100
1.0
3.5
5.0
20
50
100
20
3.5
5.0
100
:
VI 3.6V
PA
VI 3.6V
VI 5.5V
PA VI 0.0V
mA VI 0.0V
mA VI 0.0V
PA VO 3.6V
PA VO 3.6V
PA VO 5.5V
PA VO 0.0V
mA
mA
PA VO 5.5V
IOFF
Power Down
Input Leakage
C14–C17, HLHIN
0.0
0.0
100
PA VI 5.5V
IOFF—ICC
IOFF—ICC2
ICC
PowerDown
Leakage to VCC
Power Down Leakage
to VCC—Cable
Maximum Supply
Current
0.0
0.0
250
0.0
0.0
250
3.6
3.6
45
3.6
5.5
70
Note 5: Output impedance is measured with the output active LOW and active HIGH (HD HIGH).
PA (Note 6)
PA (Note 6)
mA VI VCC or GND
VI VCC or GND
Note 6: Power-down leakage to VCC or VCC—Cable is tested by simultaneously forcing all pins on the cable-side (B1–B8, Y9–Y13, PLH, C14–C17 and HLHIN)
to 5.5V and measuring the resulting ICC or ICC—Cable.
Note 7: This parameter is guaranteed but not tested, characterized only.
www.fairchildsemi.com
4