Philips Semiconductors
Hex inverting Schmitt-trigger
Product specification
74LV14
ABSOLUTE MAXIMUM RATINGS1, 2
In accordance with the Absolute Maximum Rating System (IEC 134).
Voltages are referenced to GND (ground = 0V).
SYMBOL
PARAMETER
CONDITIONS
VCC
"IIK
"IOK
"IO
DC supply voltage
DC input diode current
DC output diode current
DC output source or sink current
– standard outputs
VI < –0.5 or VI > VCC + 0.5V
VO < –0.5 or VO > VCC + 0.5V
–0.5V < VO < VCC + 0.5V
RATING
–0.5 to +7.0
20
50
25
UNIT
V
mA
mA
mA
"IGND,
"ICC
DC VCC or GND current for types with
– standard outputs
50
mA
Tstg
Storage temperature range
–65 to +150
°C
Power dissipation per package
for temperature range: –40 to +125°C
PTOT
– plastic DIL
– plastic mini-pack (SO)
above +70°C derate linearly with 12 mW/K
750
above +70°C derate linearly with 8 mW/K
500
mW
– plastic shrink mini-pack (SSOP and TSSOP) above +60°C derate linearly with 5.5 mW/K
400
NOTES:
1. Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the
device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
2. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
DC ELECTRICAL CHARACTERISTICS
Over recommended operating conditions. Voltages are referenced to GND (ground = 0V).
SYMBOL PARAMETER
TEST CONDITIONS
VCC = 1.2V; VI = VIH or VIL; –IO = 100µA
VCC = 2.0V; VI = VIH or VIL; –IO = 100µA
VOH
HIGH level output
voltage; all outputs
VCC = 2.7V; VI = VIH or VIL; –IO = 100µA
VCC = 3.0V; VI = VIH or VIL; –IO = 100µA
VCC = 4.5V; VI = VIH or VIL; –IO = 100µA
VOH
HIGH level output
voltage;
STANDARD
VCC = 3.0V; VI = VIH or VIL; –IO = 6mA
outputs
VCC = 4.5V; VI = VIH or VIL; –IO = 12mA
LIMITS
-40°C to +85°C
MIN
TYP1 MAX
1.2
1.8
2.0
2.5
2.7
2.8
3.0
4.3
4.5
2.40
2.82
3.60
4.20
VCC = 1.2V; VI = VIH or VIL; IO = 100µA
VCC = 2.0V; VI = VIH or VIL; IO = 100µA
VOL
LOW level output
voltage; all outputs
VCC = 2.7V; VI = VIH or VIL; IO = 100µA
VCC = 3.0V; VI = VIH or VIL; IO = 100µA
VCC = 4.5V; VI = VIH or VIL; IO = 100µA
VOL
LOW level output
voltage;
STANDARD
VCC = 3.0V; VI = VIH or VIL; IO = 6mA
outputs
VCC = 4.5V; VI = VIH or VIL; IO = 12mA
0
0
0.2
0
0.2
0
0.2
0
0.2
0.25
0.40
0.35
0.55
II
Input leakage
current
VCC = 5.5V; VI = VCC or GND
1.0
ICC
Quiescent supply
current; SSI
VCC = 5.5V; VI = VCC or GND; IO = 0
20.0
Additional
ICC quiescent supply VCC = 2.7V to 3.6V; VI = VCC – 0.6V
500
current
NOTE:
1. All typical values are measured at Tamb = 25°C.
-40°C to +125°C
MIN
MAX
1.8
2.5
2.8
4.3
2.20
3.50
0.2
0.2
0.2
0.2
0.50
0.65
1.0
40
850
UNIT
V
V
V
V
µA
µA
µA