datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

DM74LS125AM View Datasheet(PDF) - Fairchild Semiconductor

Part Name
Description
View to exact match
DM74LS125AM
Fairchild
Fairchild Semiconductor Fairchild
DM74LS125AM Datasheet PDF : 5 Pages
1 2 3 4 5
Absolute Maximum Ratings(Note 1)
Supply Voltage
7V
Input Voltage
7V
Operating Free Air Temperature Range 0°C to +70°C
Storage Temperature Range
65°C to +150°C
Note 1: The “Absolute Maximum Ratings” are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The “Recommended Operating Conditions” table will define the conditions
for actual device operation.
Recommended Operating Conditions
Symbol
VCC
VIH
VIL
IOH
IOL
TA
Parameter
Supply Voltage
HIGH Level Input Voltage
LOW Level Input Voltage
HIGH Level Output Current
LOW Level Output Current
Free Air Operating Temperature
Min
Nom
Max
4.75
5
5.25
2
0.8
2.6
24
0
70
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted)
Symbol
Parameter
Conditions
Min
VI
Input Clamp Voltage
VCC = Min, II = −18 mA
VOH
HIGH Level
Output Voltage
VCC = Min, IOH = Max
2.4
VIL = Max, VIH = Min
VOL
LOW Level
VCC = Min, IOL = Max
Output Voltage
VIL = Max
IOL = 12 mA, VCC = Min
II
Input Current @ Max Input Voltage
VCC = Max, VI = 7V
IIH
HIGH Level Input Current
VCC = Max, VI = 2.7V
IIL
LOW Level Input Current
VCC = Max, VI = 0.4V
IOZH
Off-State Output Current with
VCC = Max, VO = 2.4V
HIGH Level Output Voltage Applied
VIH = Min, VIL = Max
IOZL
Off-State Output Current with
VCC = Max, VO = 0.4V
LOW Level Output Voltage Applied
VIH = Min, VIL = Max
IOS
Short Circuit Output Current
VCC = Max (Note 3)
20
ICC
Supply Current
Note 2: All typicals are at VCC = 5V, TA = 25°C.
VCC = Max (Note 4)
Note 3: Not more than one output should be shorted at a time, and the duration should not exceed one second.
Note 4: ICC is measured with the data control (C) inputs at 4.5V and the data inputs grounded.
Typ
(Note 2)
3.4
0.35
0.25
11
Max
1.5
0.5
0.4
0.1
20
0.4
20
20
100
20
Switching Characteristics
at VCC = 5V and TA = 25°C
Symbol
Parameter
tPLH
Propagation Delay Time LOW-to-HIGH Level Output
tPHL
Propagation Delay Time HIGH-to-LOW Level Output
tPZH
Output Enable Time to HIGH Level Output
tPZL
Output Enable Time to LOW Level Output
tPHZ
Output Disable Time from HIGH Level Output (Note 5)
tPLZ
Output Disable Time from LOW Level Output (Note 5)
Note 5: CL = 5pF.
RL = 667
CL = 50 pF
CL = 150 pF
Min
Max
Min
Max
15
21
18
22
25
35
25
40
20
20
Units
V
V
V
mA
mA
°C
Units
V
V
V
mA
µA
mA
µA
µA
mA
mA
Units
ns
ns
ns
ns
ns
ns
www.fairchildsemi.com
2
 

Share Link: 