Philips Semiconductors
Buffer with open-drain output
Product specification
74AHC1G07;
74AHCT1G07
74AHCT1G family
Over recommended operating conditions; voltages are referenced to GND (ground = 0 V).
TEST CONDITIONS
Tamb (°C)
SYMBOL PARAMETER
OTHER
25
−40 to +85 −40 to +125 UNIT
VCC (V)
MIN. TYP. MAX. MIN. MAX. MIN. MAX.
VIH
HIGH-level input
voltage
4.5 to 5.5 2.0 −
−
2.0 −
2.0 −
V
VIL
LOW-level input
voltage
4.5 to 5.5 −
−
0.8 −
0.8 −
0.8 V
VOL
LOW-level output VI = VIH or VIL; 4.5
−
0
0.1 −
0.1 −
0.1 V
voltage
IO = 50 µA
VI = VIH or VIL; 4.5
IO = 8 mA
−
−
0.36 −
0.44 −
0.55 V
II
input leakage VI = VCC or GND 5.5
−
−
0.1 −
1.0 −
2.0 µA
current
IOZ
3-state output VI = VIH or VIL; 5.5
−
−
±0.25 −
±2.5 −
±10.0 µA
OFF-state
VO = VCC or GND
current
ICC
∆ICC
CI
quiescent supply VI = VCC or GND; 5.5
−
current
IO = 0
additional
VI = 3.4 V;
quiescent supply other inputs at
4.5 to 5.5 −
current per input VCC or GND;
pin
IO = 0
input
−
−
capacitance
−
1.0 −
−
1.35 −
1.5 10 −
10 −
1.5 −
10 −
20 µA
1.5 mA
10 pF
2000 May 02
7