Philips Semiconductors
Octal inverting buffer (3-State)
Product specification
74ABT240
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
VCC
VI
VIH
VIL
IOH
IOL
t/v
Tamb
DC supply voltage
Input voltage
High-level input voltage
Low-level Input voltage
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature range
LIMITS
Min
Max
4.5
5.5
0
VCC
2.0
0.8
–32
64
0
10
–40
+85
UNIT
V
V
V
V
mA
mA
ns/V
°C
DC ELECTRICAL CHARACTERISTICS
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
Tamb = +25°C
Tamb = –40°C
to +85°C
UNIT
Min Typ Max Min Max
VIK
Input clamp voltage
VCC = 4.5V; IIK = –18mA
–0.9 –1.2
–1.2 V
VCC = 4.5V; IOH = –3mA; VI = VIL or VIH
2.5 2.9
2.5
V
VOH High-level output voltage
VCC = 5.0V; IOH = –3mA; VI = VIL or VIH
3.0 3.4
3.0
V
VCC = 4.5V; IOH = –32mA; VI = VIL or VIH
2.0 2.4
2.0
V
VOL Low-level output voltage
VCC = 4.5V; IOL = 64mA; VI = VIL or VIH
0.42 0.55
0.55 V
II
Input leakage current
VCC = 5.5V; VI = GND or 5.5V
±0.01 ±1.0
±1.0 µA
IOFF
Power-off leakage current
VCC = 0.0V; VI or VO 4.5V;
±5.0 ±100
±100 µA
IPU/IPD
Power-up/down 3-state
output current3
VCC = 2.1V; VO = 0.5V; VI = GND or VCC;
V OE = Don’t care
±5.0 ±50
±50 µA
IOZH 3-State output High current VCC = 5.5V; VO = 2.7V; VI = VIL or VIH
5.0 50
50
µA
IOZL 3-State output Low current VCC = 5.5V; VO = 0.5V; VI = VIL or VIH
–5.0 –50
–50 µA
ICEX
IO
Output High leakage current
Output current1
VCC = 5.5V; VO = 5.5V; VI = GND or VCC
VCC = 5.5V; VO = 2.5V
5.0 50
50
µA
–50 –100 –180 –50 –180 mA
ICCH
VCC = 5.5V; Outputs High, VI = GND or VCC
50 250
250 µA
ICCL Quiescent supply current
VCC = 5.5V; Outputs Low, VI = GND or VCC
24
30
30 mA
ICCZ
VCC = 5.5V; Outputs 3-State;
VI = GND or VCC
50 250
250 µA
ICC
Additional supply current per Outputs 3-State, one input at 3.4V, other
input pin2
inputs at VCC or GND; VCC = 5.5V
0.5 1.5
1.5 mA
NOTES:
1. Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
2. This is the increase in supply current for each input at 3.4V.
3. This parameter is valid for any VCC between 0V and 2.1V, with a transition time of up to 10msec. From VCC = 2.1V to VCC 5V ± 10% a
transition time of up to 100µsec is permitted.
1996 Sep 10