TC4066BP/BF/BFN/BFT
Dynamic Electrical Characteristics (Ta = 25°C, VSS = 0 V, CL = 50 pF)
Characteristics
Phase difference between
input to output
Propagation delay time
(control-OUT)
Propagation delay time
(control -OUT)
Max control input repetition
rate
3dB cutoff frequency
Total harmonic distortion
50dB feed through
frequency
50dB crosstalk frequency
Crosstalk
(control-OUT)
Input capacitance
Feed through capacitance
Symbol
φI-O
CL = 50 pF
tpZL
tpZH
RL = 1 kΩ
CL = 50 pF
tpLZ
tpHZ
RL = 1 kΩ
CL = 50 pF
fmax (C)
RL = 1 kΩ
CL = 50 pF
fmax (I-O)
RL = 1 kΩ
CL = 15 pF
RL = 10 kΩ
f = 1 kHz
Test Condition
VSS VDD Min Typ. Max Unit
(V) (V)
05
15
40
0 10
8
20
ns
0 15
5
15
05
55 120
0 10
25
40
ns
0 15
20
30
05
45
80
0 10
30
70
ns
0 15
25
60
05
10
0 10
12
MHz
0 15
12
5 5
30
MHz
(Note 1)
5 5
0.03
%
(Note 2)
RL = 1 kΩ
(Note 3) 5 5
600
kHz
CIN
CIN-OUT
RL = 1 kΩ
RIN = 1 kΩ
ROUT = 10 kΩ
CL = 15 pF
Control input
Switch I/O
(Note 4) 5 5
05
0 10
0 15
1
MHz
200
400
mV
600
5
7.5
pF
10
0.5
pF
Note 1:
Sine wave of ±2.5 p-p shall be used for Vis and the frequency of 20 log 10
VOS
Vis
= −3dB shall be fmax.
Note 2: Vis shall be sine wave of ±2.5 Vp-p
Note 3:
Sine wave of ±2.5 Vp-p shall be used for Vis and the frequency of 20 log 10
VOUT
Vis
= −50dB shall be
feed-through.
Note 4:
Sine wave of ±2.5 Vp-p shall be used for Vis and the frequency of 20 log 10
VOUT
Vis
= −50dB shall be
crosstalk.
4