M29F102BB
DC AND AC PARAMETERS
This section summarizes the operating measure-
ment conditions, and the DC and AC characteris-
tics of the device. The parameters in the DC and
AC characteristics Tables that follow, are derived
from tests performed under the Measurement
Conditions summarized in Table 9, Operating and
AC Measurement Conditions. Designers should
check that the operating conditions in their circuit
match the operating conditions when relying on
the quoted parameters.
Table 8. Operating and AC Measurement Conditions
Parameter
M29F102BB
Unit
Min
Max
Load Capacitance (CL)
30
pF
Input Rise and Fall Times
10
ns
Input Pulse Voltages
0
3
V
Input and Output Timing Ref. Voltages
1.5
V
Figure 7. AC Testing Input Output Waveform
Figure 8. AC Testing Load Circuit
1.3V
3V
1N914
1.5V
0V
3.3kΩ
AI01417
DEVICE
UNDER
TEST
OUT
CL = 30pF
CL includes JIG capacitance
Table 9. Capacitance (TA = 25 °C, f = 1 MHz)
Symbol
Parameter
Test Condition
CIN
Input Capacitance
VIN = 0V
COUT
Output Capacitance
Note: Sampled only, not 100% tested.
VOUT = 0V
Min
Max
6
12
AI02979
Unit
pF
pF
14/24