MC-4516CB647
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
Operating current
ICC1 Burst length = 1
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC2PS CKE VIL(MAX.), tCK =
Precharge standby current in ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
non power down mode
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH(MIN.), tCK =
Input signals are stable.
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC3PS CKE VIL(MAX.), tCK =
Active standby current in
non power down mode
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during 30 ns.
Operating current
ICC3NS CKE VIH(MIN.), tCK =
Input signals are stable.
ICC4 tCK tCK(MIN.)
/CAS latency = 2
(Burst mode)
IO = 0 mA
/CAS latency = 3
CBR (Auto) refresh current
ICC5 tRC tRC(MIN.)
/CAS latency = 2
/CAS latency = 3
Self refresh current
ICC6 CKE 0.2 V
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
High level output voltage
VOH IO = – 4.0 mA
Low level output voltage
VOL IO = + 4.0 mA
MIN. MAX. Unit Notes
800 mA 1
840
8 mA
8
160 mA
64
40 mA
32
240 mA
160
960 mA 2
1,240
1,840 mA 3
1,920
16 mA
– 8 + 8 µA
– 1.5 + 1.5 µA
2.4
V
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6