Nexperia
tW
VI 90 %
negative
pulse
VM
10 %
0V
tf
tr
VI
positive
pulse
90 %
VM
10 %
0V
tW
74HC4316; 74HCT4316
Quad single-pole single-throw analog switch
VM
tr
tf
VM
PULSE
GENERATOR
VCC Vis
VI
Vos
DUT
RT
VCC
RL S1
open
CL
GND
VEE
aaa-024858
Test data is given in Table 11.
Definitions test circuit:
RT = Termination resistance should be equal to output impedance Zo of the pulse generator.
CL = Load capacitance including jig and probe capacitance.
RL = Load resistance.
S1 = Test selection switch.
Fig. 15. Test circuit for measuring switching times
Table 11. Test data
Test
Input
E
nS
VI
tPHL, tPLH [2]
tPHZ, tPZH [2]
tPLZ, tPZL [2]
Switch nY (nZ) tr, tf
Vis
at fmax
GND to VCC < 2 ns
VCC
< 2 ns
VEE
< 2 ns
other [1]
6 ns
6 ns
6 ns
Output
Switch nZ (nY)
CL
RL
50 pF
-
50 pF, 15 pF 1 kΩ
50 pF, 15 pF 1 kΩ
[1] tr = tf = 6 ns; when measuring fmax, there is no constraint to tr and tf with 50 % duty factor.
[2] VI values:
For 74HC4316: VI = VCC
For 74HCT4316: VI = 3 V
S1 position
open
VEE
VCC
74HC_HCT4316
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 4 — 15 October 2018
© Nexperia B.V. 2018. All rights reserved
14 / 24