First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
NXP Semiconductors
74HC4017; 74HCT4017
Johnson decade counter with 10 decoded outputs
Table 7. Dynamic characteristics …continued
GND = 0 V; tr = tf = 6 ns; CL = 50 pF; see Figure 11.
Symbol Parameter
Conditions
25 °C
40 °C to +85 °C 40 °C to +125 °C Unit
Min Typ Max Min Max
Min
Max
tt
transition time see Figure 10
[2]
VCC = 4.5 V
- 7 15
-
19
-
22 ns
tW
pulse width
CP0 and CP1 (HIGH or
LOW); see Figure 9
VCC = 4.5 V
16 7 -
20
-
24
- ns
MR (HIGH); see Figure 9
VCC = 4.5 V
16 4 -
20
-
24
- ns
tsu
set-up time
CP1 to CP0; CP0 to CP1;
see Figure 8
VCC = 4.5 V
10 3 -
13
-
15
- ns
th
hold time
CP1 to CP0; CP0 to CP1;
see Figure 8
VCC = 4.5 V
10 6 -
13
-
15
- ns
trec
recovery time MR to CP0 and
MR to CP1; see Figure 9
VCC = 4.5 V
5 5 -
5
-
5
- ns
fmax
maximum
CP0 or CP1; see Figure 9
frequency
VCC = 4.5 V
30 61 -
24
-
20
- MHz
VCC = 5.0 V;
CL = 15 pF
- 67 -
-
-
-
- MHz
CPD
power
VI = GND to VCC 1.5 V; [3] -
36
-
-
-
-
- pF
dissipation
VCC = 5 V; fi = 1 MHz
capacitance
[1] tpd is the same as tPHL and tPLH.
[2] tt is the same as tTHL and tTLH.
[3] CPD is used to determine the dynamic power dissipation (PD in µW):
PD = CPD × VCC2 × fi × N + (CL × VCC2 × fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
(CL × VCC2 × fo) = sum of outputs.
74HC_HCT4017_3
Product data sheet
Rev. 03 — 8 January 2008
© NXP B.V. 2008. All rights reserved.
11 of 23
 