Dual buffer/line driver; 3-state
Table 8. Dynamic characteristics …continued
GND = 0 V; for test circuit see Figure 8.
Symbol Parameter Conditions
ten
enable time 1OE to 1Y; see Figure 6
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
2OE to 2Y; see Figure 7
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
tdis
disable time 1OE to 1Y; see Figure 6
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
2OE to 2Y; see Figure 7
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
CPD
power
per buffer;
dissipation CL = 50 pF; fi = 1 MHz;
capacitance VI = GND to VCC
25 °C
40 °C to +85 °C 40 °C to +125 °C Unit
Min Typ Max Min Max
Min
Max
[1]
[3]
- 3.9 5.1 1.0
6.0
1.0
6.5 ns
- 5.1 7.5 1.0
8.5
1.0
9.5 ns
[1]
[3]
- 3.4 5.6 1.0
6.3
1.0
6.5 ns
- 4.8 7.5 1.0
9.0
1.0
9.5 ns
[1]
[3]
- 4.5 6.8 1.0
8.0
1.0
8.5 ns
- 6.1 8.8 1.0
10.0
1.0
11.0 ns
[1]
[3]
- 4.0 6.8 1.0
8.0
1.0
8.5 ns
- 5.7 8.8 1.0
10.0
1.0
11.0 ns
[4] -
10
-
-
-
-
-
pF
[1] tpd is the same as tPLH and tPHL.
ten is the same as tPZL and tPZH.
tdis is the same as tPLZ and tPHZ.
[2] Typical values are measured at VCC = 3.3 V.
[3] Typical values are measured at VCC = 5.0 V.
[4] CPD is used to determine the dynamic power dissipation PD (µW).
PD = CPD × VCC2 × fi + (CL × VCC2 × fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in Volts.
74AHC_AHCT2G241_2
Product data sheet
Rev. 02 — 13 January 2009