datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

N133I1-L01 View Datasheet(PDF) - Unspecified

Part Name
Description
View to exact match
N133I1-L01 Datasheet PDF : 28 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Issued Date: May. 15, 2006
Model No.: N133I1 - L01
Approval
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item
Storage Temperature
Storage Humidity
Operating Ambient Temperature
Operating Humidity
Shock (Non-Operating)
Vibration (Non-Operating)
Symbol
TST
HST
TOP
HOP
SNOP
VNOP
Value
Min.
Max.
-20
+60
10
90
0
+50
20
90
-
200/2
-
1.5
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Unit
ºC
%
ºC
%
G/ms
G
Note
(1)
(1), (2)
(3), (5)
(4), (5)
Relative Humidity (%RH)
100
90
80
60
Operating Range
40
20
10
Storage Range
-40
-20
0
20
40
60
80
Temperature (ºC)
Note (2) The temperature of panel surface should be 0 ºC Min. and 50 ºC Max.
Note (3) 1 time for ± X, ± Y, ± Z. for Condition (200G / 2ms) is half Sine Wave,
Note (4) 10 ~ 200 Hz, 0.5 Hr / Cycle, 1 cycles for each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
The fixing condition is shown as below:
At Room Temperature
LCD Module
Side Mount Fixing Screw
Gap=2mm
Bracket
Side Mount Fixing Screw
Stage
5 / 28
Version 2.1
 