Approval
2 ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item
Symbol
Storage Temperature
TST
Operating Ambient Temperature
TOP
Shock (Non-Operating)
SNOP
Vibration (Non-Operating)
VNOP
Note (1) (a) 90 %RH Max. (Ta 40 ºC).
Value
Min.
Max.
-20
+60
0
+50
-
220/2
-
1.5
Unit
ºC
ºC
G/ms
G
Note
(1)
(1), (2)
(3), (5)
(4), (5)
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (2) The temperature of panel display surface area should be 0 ºC Min. and 60 ºC Max.
Relative Humidity (%RH)
100
90
80
60
Operating Range
40
20
10
Storage Range
-40
-20
0
20
40
60
80
Temperature (ºC)
Note (3) 1 time for ± X, ± Y, ± Z. for Condition (200G / 2ms) is half Sine Wave,.
Note (4) 10 ~ 500 Hz, 30 min/cycle,1cycles for each X, Y, Z axis.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid
enough so that the module would not be twisted or bent by the fixture.
The fixing condition is shown as below:
At Room Temperature
LCD Module
Side Mount Fixing Screw
Gap=2mm
Bracket
Side Mount Fixing Screw
Stage