FS6330
AMI
AMI Semiconductor AMI
FS6330 Datasheet PDF : 6 Pages
1 2 3 4 5 6
FS6330
LAN Hub Clock Generator IC
AMERICAN MICROSYSTEMS, INC.
Preliminary Information
May 2000
Table 2: Pin Descriptions
Key: AI = Analog Input; AO = Analog Output; DI = Digital Input; DIU = Input with Internal Pull-Up; DID = Input with Internal Pull-Down; DO = Digital Output; P = Power/Ground; # = Active-low pin
PIN
TYPE
NAME
DESCRIPTION
1
DO
2, 7, 12, 17
P
3
DIU
4
AO
5
AI
6, 10, 16, 20
P
8
DIU
9
DO
11, 13, 14, 15
DO
18
DO
19
DO
CLKF
VSS
SEL0
X2/REFIN
X1
VDD
SEL1
CLKG
CLKB1:4
CLKA
CLKC
Clock Output
Ground
Clock Select (LSB)
Crystal oscillator drive / external reference input
Crystal oscillator feedback
+3.3V power supply
Clock Select (MSB)
Clock Output
Four clock outputs
Clock Output
Clock Output
2.0 Electrical Specifications
Table 3: Absolute Maximum Ratings
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. These conditions represent a stress rating only, and functional operation of the device at
these or any other conditions above the operational limits noted in this specification is not implied. Exposure to maximum rating conditions for extended conditions may affect device performance,
functionality, and reliability.
PARAMETER
SYMBOL
MIN.
MAX.
UNITS
Supply Voltage (VSS = ground)
Input Voltage, dc
Output Voltage, dc
Input Clamp Current, dc (VI < 0 or VI > VDD)
Output Clamp Current, dc (VI < 0 or VI > VDD)
Storage Temperature Range (non-condensing)
Ambient Temperature Range, Under Bias
Junction Temperature
Lead Temperature (soldering, 10s)
Input Static Discharge Voltage Protection (MIL-STD 883E, Method 3015.7)
VDD
VSS-0.5
7
V
VI
VSS-0.5
VDD+0.5
V
VO
VSS-0.5
VDD+0.5
V
IIK
-50
50
mA
IOK
-50
50
mA
TS
-65
150
°C
TA
-55
125
°C
TJ
125
°C
260
°C
2
kV
CAUTION: ELECTROSTATIC SENSITIVE DEVICE
Permanent damage resulting in a loss of functionality or performance may occur if this device is subjected to a high-energy elec-
trostatic discharge.
Table 4: Operating Conditions
PARAMETER
Supply Voltage
Operating Temperature Range
SYMBOL
VDD
TA
CONDITIONS/DESCRIPTION
No airflow
2
MIN.
3.135
0
TYP.
3.3
MAX.
3.465
70
UNITS
V
°C
5.23.00
 