datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

7-1462000-6 View Datasheet(PDF) - TE Connectivity

Part Name
Description
View to exact match
7-1462000-6
Te
TE Connectivity Te
7-1462000-6 Datasheet PDF : 4 Pages
1 2 3 4
Signal Relays
MT2 Relay
n Telecom/signal relay (dry circuit, test access, ringing)
n Slim line 20x10mm (.795x.393”)
n Switching current 2A
n 2 form C contacts (2 CO, 2 changeover contacts)
n Bifurcated contacts
n Meets FCC Part 68 and ITU-T K20
AXICOM
Typical applications
Communications equipment, linecard application – analog, ISDN, xDSL,
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment, automotive Equipment
Z
Approvals
UL 508 File No. E 111441
Technical data of approved types on request
Contact Data
Contact arrangement
2 form C (2 CO)
Max. switching voltage
220VDC, 250VAC
Rated current
2A
Limiting continuous current, 85°C
2A
Contact material
AgNi, gold-covered
Contact style
bifurcated contacts
Min. recommended contact load
10mA at 20mV
Minimum switching voltage
100μV
Initial contact resistance < 70mΩ at 10mA, 20mV
Frequency of operation, without load max. 50 operations/s
Operate / release time max.
5ms/3ms
Bounce time max.
5ms
Electrical endurance
contact application 0 (≤30mV/≤10mA) min. 5x106 operations
cable load open end min. 2.5x106 operations
resistive load 150V/0.2A - 30W min. 2x105 operations
24V/1.25A - 30W min. 2x105 operations
Contact ratings, UL
N.O./N.C. Contacts -
0.4 A at 125 V ac, resistive
1.25 A at 24 V dc
2 A at 30 V dc
These ratings are for same polarity between poles.
Mechanical endurance typ. 100x106 operations
Max. DC load breaking capacity
10-2015, Rev. 0715
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
DC current [A]
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Coil Data
Magnetic system
neutral
Coil voltage range
3 to 48VDC
Max. coil temperature
115°C
Thermal resistance
< 85K/W
Coil versions, monostable
Coil
Rated Operate Limiting Release Coil Rated coil
code voltage voltage Voltage voltage resistance power
VDC
VDCmin. VDCmax. VDCmin. Ω±10%
mW
High sensitive version, 150mW
00
3
2.1
8.1
0.3
60
150
07
3.3
2.3
8.8
0.33
72
150
06
4.5
3.2
12.2
0.45
136
150
01
5
3.6
13.5
0.5
168
150
27
6
4.3
16.2
0.6
240
150
05
9
6.4
24.3
0.9
544
150
02
12
8.6
32.4
1.2
968
150
03
24
17.1
64.8
2.4
3872
150
04
48
34.1 129.6
4.8
15468 150
Sensitive version, 200mW
14
3
2
7
0.3
45
200
15
4.5
2.9
10.5
0.45
101
200
16
5
3.3
11.6
0.5
125
200
28
6
3.9
14
0.6
180
200
17
9
5.9
21
0.9
405
200
18
12
7.8
28
1.2
720
200
19
24
15.6
59.9
2.4
2880
200
20
48
31.2 112
4.8
11520 200
Sensitive version, 300mW
33
4.5
3.1
8.9
0.45
73
300
34
5
3.4
9.9
0.5
90
300
12
12
8.25 23.6
1.2
515
300
35
24
16.5
47.3
2.4
2060
300
36
48
32.5
54.6
4.8
8240
300
Standard version, 400mW
21
4.5
2.9
8.9
0.45
50
400
22
5
3.3
9.9
0.5
63
400
29
6
3.9
11.8
0.6
90
400
23
9
5.9
17.7
0.9
203
400
24
12
7.8
23.6
1.2
360
400
25
24
15.6
47.3
2.4
1440
400
26
48
31.2
94.6
4.8
5760
400
Standard version, 550mW
38
4.5
2.9
6.3
0.45
36
550
50
5
3.3
7
0.5
45
550
37
6
3.9
8.4
0.6
66
550
32
12
7.8
16.8
1.2
280
550
31
24
15.6
33.6
2.4
1050
550
30
48
31.2
67.2
4.8
4100
550
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]