datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

TXD2SL-2M-H-1.5V-X View Datasheet(PDF) - Panasonic Corporation

Part Name
Description
View to exact match
TXD2SL-2M-H-1.5V-X Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TX-D
2. Specifications
Characteristics
Contact
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*2
Rating
Single side stable
Nominal operating
power
1 coil latching
Insulation resistance (Initial)
Between open contacts
Breakdown
voltage (Initial)
Between contact and coil
Electrical
characteristics
Between contact sets
Between open contacts
Surge breakdown
voltage (Initial)
Between contacts and
coil*1
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Mechanical
characteristics
Expected life
Conditions
Unit weight
Shock
resistance
Vibration
resistance
Mechanical
Functional
Destructive
Functional
Destructive
Electrical
Conditions for operation, transport and
storage*3
Max. operating speed (at rated load)
Specifications
2 Form C
2 Form D (M.B.B.type)*1
Max. 100 m(By voltage drop 6 V DC 1A)
Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Standard contact: 2 A 30 V DC,
AgPd contact: 1 A 30 V DC (resistive load)
1 A 30 V DC (resistive load)
Standard contact: 60 W (DC),
AgPd contact: 30 W (DC) (resistive load)
30 W (DC) (resistive load)
220 V DC
110 V DC
Standard contact: 2 A, AgPd contact: 1 A
1A
10µA10mV DC
Surge breakdown voltage
2,500 V and 6,000 V types:
200mW (1.5 to 12 V DC), 230mW (24 V DC)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
280mW (1.5 to 12 V DC), 310mW (24 V DC)
250mW (1.5 to 12 V DC), 270mW (24 V DC)
Surge breakdown voltage
2,500 V and 6,000 V types:
150mW (1.5 to 12 V DC), 170mW (24 V DC)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
230mW (1.5 to 12 V DC), 250mW (24 V DC)
Min. 1,000M(at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Surge breakdown voltage
2,500 V and 6,000 V types:
1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
1,500 Vrms for 1min. (Detection current: 10mA)
500 Vrms for 1min. (Detection current: 10mA)
Surge breakdown voltage 2,500 V type:
2,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown voltage 6,000 V and
6,000 V (High breakdown voltage) types:
3,000 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160µs) (FCC Part 68)
Surge breakdown voltage 2,500 V type:
2,500 V, 2 × 10µs (Telcordia)
Surge breakdown voltage 6,000 V and 6,000 V
(High breakdown voltage) types:
6,000 V, 1.2 × 50µs
2,500 V, 2 × 10µs (Telcordia)
Max. 50°C 122°F
(By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 2A [1A: M.B.B.].)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 750 m/s2
(Half-wave pulse of sine wave: 6 ms;
detection time: 10µs.)
Min. 500 m/s2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs.)
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 108 (at 180 cpm)
Min. 107 (at 180 cpm)
Min. 105 (2 A 30 V DC resistive),
Min. 5×105 (1 A 30 V DC resistive) (at 20 cpm)
Min. 105 (1 A 30 V DC resistive) (at 20 cpm)
Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 2 g .071 oz
Notes: *1 M.B.B. type models are only available in 2,500 V surge breakdown voltage type.
*2 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type or SX relays are available for low level load switching [10V DC, 10mA max. level])
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
 

Share Link: 