Absolute Maximum Ratings at TA = 25°C
Parameter
Red
Yellow
Green
Units
Peak Forward Current
Average Forward Current[1]
DC Current[2]
Power Dissipation[3]
Reverse Voltage (IR = 100 µA)
Transient Forward Current[4]
(10 µsec Pulse)
LED Junction Temperature
Operating Temperature Range
90
60
25
20
30
20
135
85
5
5
500
500
90
mA
25
mA
30
mA
135
mW
5
V
500
mA
110
110
110
°C
-55 to +100
-55 to +100
-20 to +100
°C
Storage Temperature Range
Lead Soldering Temperature
[1.6 mm (0.063 in.) from body]
-55 to +100
260°C for 5 seconds
Notes:
1. See Figure 5 (Red), 10 (Yellow), or 15 (Green) to establish pulsed operating conditions.
2. For Red and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.