110 WATT SWITCHING POWER SUPPLIES
DESCRIPTION
The PU110 series of compact, open PCB constructed,
AC-DC switching power supplies are capable of delivering
72 to 110 watts of continuous power at 25 CFM forced air
cooling or 52 to 80 watts at convection cooling. They
operate at 85 to 264VAC input voltage without the need of
a selector strap. They are ideally suited for use in small to
medium size digitally-based systems, such as
point-of-sale equipment, microprocessor based systems,
and telecom equipment. All models meet the safety
requirements of UL, CSA and IEC.
PU110 SERIES
( LV D )
RoHS
FEATURES
Recognized or certified by UL, CSA and TÜV
Power Fail Detect (PFD) signal
100% burn-in
Wide input range 85 to 264VAC
Input surge current protection
Overvoltage protection
Overcurrent protection
Compliant with RoHS requirements
INPUT SPECIFICATIONS
Input voltage
85 to 264VAC
Input frequency
47 to 63Hz
Input current
3.20Armsfor 115VAC
1.80Armsfor 230VAC
Earth leakage current
(Touch current)
0.40mA max. @ 115VAC, 60Hz
0.75mA max. @ 230VAC, 50Hz
Safety Standard Approvals
UL 60950-1
CSA C22.2 No. 60950-1
TÜV EN60950-1
OUTPUT SPECIFICATIONS
Output voltage/currentSee rating chart
Total output power
110 watts maximum at 25 CFM
forced air cooling or 80 watts
maximum at convection cooling
Ripple and noise
1peak to peak maximum
Overvoltage protectionProvided on output #1 only; set at
112-132of its nominal output
voltage
Overcurrent protectionAll outputs protected to short circuit
conditions
Temperature coefficientAll outputs ±0.04/ºC maximum
Transient responseMaximum excursion of 4or
better on all models, recovering
to 1of final value within 500us
after a 25step load change
PFD signal
TTL logic high for normal operation
and TTL logic low upon loss of
input power. This signal appears at
least 1ms prior to +5V output
dropping
5below its nominal value. This
signal also provides a minimum
delay of 100ms after +5V is within
regulation.
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
Cooling:
0ºC to +70ºC
-40ºC to +85ºC
5to 95non-condensing
Derate from 100at +50ºC
linearly to 50at +70ºC
110 watts continuous output power
at 25 CFM forced air cooling or
80 watts at convection cooling
GENERAL SPECIFICATIONS
Switching frequency: 20KHz to 250KHz, varies with load and
line
Efficiency:
70minimum on single output models
with Vo12V, 65% minimum on the others
Hold-up time:
Line regulation:
12 msec minimum at 110VAC
±0.5maximum at full load
Inrush current:
Withstand voltage:
15 amps @ 115VAC or 30 amps
@ 230VAC, at 25ºC cold start
3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF
400,000 hours minimum at full load
at 25ºC ambient, calculated per
MIL-HDBK-217F
EMC Performance (EN55024)
EN55022:
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class A
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ± 8KV air and ± 4KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ± 1KV
EN61000-4-5:
Surge, ± 1KV diff., ± 2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 1A/m
EN61000-4-11:
Voltage dips, 30% reduction for
500ms and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 sales@trumpower.com www.TRUMPower.com
 