PRELIMINARY NSootimcee: pTahriasmisentroict alimfinitsalasrpeescuifbicjeactitotno. change.
MITSUBISHI MICROCOMPUTERS
M37754FFCGP
M37754FFCHP
SHINGLE-CHIP 16-BIT CMOS MICROCOMPUTER FLASH MEMORY VERSION
Reset command
The reset command provides a means of stopping execution of the
erase or program command safely. If the user inputs command code
FF16 in the second cycle after inputting the erase or program com-
mand in the first cycle and again input command code FF16 in the
third cycle, the erase or program command is disabled (i.e., reset),
and the M37754FFCGP and the M37754FFCHP are placed in the
read mode. If the reset command is executed, the contents of the
memory does not change.
Device identification code command
By inputting command code 9016 in the first cycle, the user can read
out the device identification code. The command code is latched into
___
the internal command latch at the rising edge of the WE input. At this
time, the user can read out manufacture’s code 1C16 (i.e.,
MITSUBISHI) by inputting 000016 to the address input pins in the
second cycle; the user can read out device code D016 (i. e., 1M-bit
flash memory) by inputting 000116.
These command and data codes are input/output at the same timing
as for read.