MITSUBISHI MICROCOMPUTERS
3886 Group
SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER
(2) START condition generating procedure using multi-master
1. Procedure example (The necessary conditions of the generat-
ing procedure are described as the following 2 to 5.
LDA —
(Taking out of slave address value)
SEI
(Interrupt disabled)
BBS 5, S1, BUSBUSY (BB flag confirming and branch pro-
cess)
BUSFREE:
STA S0
(Writing of slave address value)
LDM #$F0, S1
(Trigger of START condition generating)
CLI
(Interrupt enabled)
BUSBUSY:
CLI
(Interrupt enabled)
2. Use “Branch on Bit Set” of “BBS 5, $0014, –” for the BB flag
confirming and branch process.
3. Use “STA $12, STX $12” or “STY $12” of the zero page ad-
dressing instruction for writing the slave address value to the
I2C data shift register.
4. Execute the branch instruction of above 2 and the store instruc-
tion of above 3 continuously shown the above procedure
example.
5. Disable interrupts during the following three process steps:
• BB flag confirming
• Writing of slave address value
• Trigger of START condition generating
When the condition of the BB flag is bus busy, enable interrupts
immediately.
(3) RESTART condition generating procedure
This cannot be applied when the external memory is used and the
bus cycle is extended by ONW function.
1. Procedure example (The necessary conditions of the generat-
ing procedure are described as the following 2 to 4.)
Execute the following procedure when the PIN bit is “0.”
LDM #$00, S1
LDA —
SEI
STA S0
LDM #$F0, S1
CLI
(Select slave receive mode)
(Taking out of slave address value)
(Interrupt disabled)
(Writing of slave address value)
(Trigger of RESTART condition generating)
(Interrupt enabled)
2. Select the slave receive mode when the PIN bit is “0.” Do not
write “1” to the PIN bit. Neither “0” nor “1” is specified for the
writing to the BB bit.
The TRX bit becomes “0” and the SDA pin is released.
3. The SCL pin is released by writing the slave address value to
the I2C data shift register.
4. Disable interrupts during the following two process steps:
• Writing of slave address value
• Trigger of RESTART condition generating
(4) Writing to I2C status register
Do not execute an instruction to set the PIN bit to “1” from “0” and
an instruction to set the MST and TRX bits to “0” from “1” simulta-
neously. It is because it may enter the state that the SCL pin is
released and the SDA pin is released after about one machine
cycle. Do not execute an instruction to set the MST and TRX bits
to “0” from “1” simultaneously when the PIN bit is “1.” It is because
it may become the same as above.
(5) Process of after STOP condition generating
Do not write data in the I2C data shift register S0 and the I2C sta-
tus register S1 until the bus busy flag BB becomes “0” after
generating the STOP condition in the master mode. It is because
the STOP condition waveform might not be normally generated.
Reading to the above registers do not have the problem.
(6) STOP condition input at 7th clock pulse
In the slave mode, the STOP condition is input at the 7th clock
pulse while receiving a slave address or data. As the clock pulse
is continuously input, the SDA line may be held at LOW even if
flag BB is set to “0” (only for M38867M8A and M38867E8).
Countermeasure:
Write dummy data to the I2C shift register or reset the ES0 bit in
the S1D register (ES0 = “L” ES0 = “H”) during a stop condition
interrupt routine with flag PIN = “1”.
Note: Do not use the read-modify-write instruction at this time.
Furthermore, when the ES0 bit is set to “0”, it becomes a
general-purpose port; so that the port must be set to input
mode or “H”.
(7) ES0 bit switch
In standard clock mode when SSC = “000102” or in high-speed
clock mode, flag BB may switch to “1” if ES0 bit is set to “1” when
SDA is “L”.
Countermeasure:
Set ES0 to “1” when SDA is “H”.
50
 