LC72191, 72191M, 72191JM
Pin Functions
Pin No. Symbol
1
XIN
24
XOUT
I/O
Input
Output
Type
Xtal OSC
19
FMIN
Input
Local oscillator signal
input
18
AMIN
Input
Local oscillator signal
input
Function
• Connections for a 7.2 MHz crystal oscillator
• FMIN is selected when DV in the serial input data is set to 1.
• Input frequency range: 10 to 130 MHz (70 mVrms minimum)
• The signal passes through an internal divide-by-two prescaler and is then supplied to
the swallow counter.
• Although the divisor setting is in the range 256 to 65,536, the actual divisor will be twice
the set value due to the presence of the internal divide-by-two prescaler.
• AMIN is selected when DV in the serial input data is set to 0.
• When SP in the serial input data is set to 1:
— Input frequency range: 2 to 40 MHz (70 mVrms minimum).
— The signal is supplied directly to the swallow counter without passing through the
internal divide-by-two prescaler.
— The divisor setting is in the range 256 to 65,536 and the actual divisor will be the
value set.
• When SP in the serial input data is set to 0:
— Input frequency range: 0.5 to 10 MHz (70 mVrms minimum).
— The signal is supplied directly to a 12-bit programmable divider.
— The divisor setting is in the range 4 to 4,096 and the actual divisor will be the
value set.
• PLL charge pump outputs. High levels are output from PD1 and PD2 when the local
21
22
PD1
PD2
Three-state Charge pump outputs
oscillator frequency divided by n is higher than the reference frequency, and low levels
are output when that frequency is lower than the reference frequency.
These pins go to the floating state when the frequencies agree.
6
SYC
N-channel
open drain
Controller clock
20
VDD
Power supply
23
VSS
Ground
2
CE
Input*1 Chip enable
4
CL
Input*1 Clock
• SYC is a controller clock source. The LC72191 outputs a 400 kHz 66% duty signal
from this pin after power is applied.
• The LC72191 power supply pin. A voltage of between 4.5 and 6.5 V must be provided
when the PLL is operating. The supply voltage can be lowered to 3.5 V when only
operating the crystal oscillator circuit to acquire the controller clock and the clock time
base outputs.
• The LC72191 ground pin
• This pin must be set high when inputting serial data (via DI) or when outputting serial
data (via DO).
• The clock input used for data signal synchronization during serial data input (via DI) or
output (via DO).
3
DI
Input*1 Input data
• Input pin used when transferring serial data from the controller to the LC72191.
• A total of 36 bits of data must be supplied to set up the LC72191 initial state.
Output
5
DO
(N-channel Output data
open drain)
• Output pin used when transferring serial data to the controller from the LC72191.
• A total of 28 bits from an internal shift register can be output in synchronization with the
CL signal.
9
OUT0
10
OUT1
11
OUT2
12
OUT3
Output*2 Output port
13
OUT4
14
OUT5
17
OUT6
• These pins latch bits O0 to O6 in the serial data transferred from the controller, invert
that data and output the inverted data in parallel.
• The OUT0 pin can also be used to output an 8 Hz clock time base signal.
(When TB is 1.)
• OUT1 and OUT2 are complementary outputs.
• OUT0, OUT3, OUT4, OUT5 and OUT6 are N-channel open drain outputs that can
handle up to 13 V.
Note: *1. The high and low level input voltages for the CE, CL, DI, IN0 and IN1 pins are VIH = 2.2 to 6.5 V and VIL = 0 to 0.7 V, regardless of the power
supply voltage VDD.
*2. Since the output port states are undefined when power is first applied, transfer the control data quickly.
Continued on next page.